Product specification

SUMIPAX ODS Particle size
(μm)
Pore size
(Å)
Specific surface area
(m2/g)
Pore volume
(mL/g)
Carbon content
(%)
Useful pH range Metal impurities
(ppm)
D series 3.5 130 280 1.0 15 2.5~7.5 Both elements less than 10ppm
Al, Fe, Ti, Zr, Ca

Performance evaluation

Applications

Column durability against water elution

Organic acids

Ultra-low pressure column with particle size of 3mm ODS D-210SLP series

Low column pressure was realized by particle size of 3 μm

By eliminating minute particles of packing materials and improving the filling method, the lowest level column pressure was realized.
They allow analysis using an ultra-low pressure while ensuring high performance of the filler with a particle size of 3 μm. As shown in Figure-1, the column pressure is extremely low not only for acetonitrile but also for methanol with which the column pressure becomes higher depending on the mixing ratio with water, realizing good separation in a short time by a large number of theoretical plate.

Column pressure

Fig. 1 Comparison of column pressure in terms of mobile phase composition

Durability

As the mobile phase, a methanol/water gradient phase was selected for its huge impact on the column pressure depending on the mixing ratio. As a result of column durability test, there was no major change in the number of theoretical plate after injecting 400 times (Figure-2).

Maximum column pressure test conditions

Post-durability test evaluation conditions

Fig. 2 Maximum column pressure test

Product list

SUMIPAX ODS D-210SLP (3μm)

Product name
SUMIPAX ODS
Internal diameter(mm) Length(mm) Product code
D-210SLP 2 50 AD210S2005W
150 AD210S2015W
4.6 50 AD210S4605W
100 AD210S4610W
150 AD210S4615W
250 AD210S4625W

SUMIPAX ODS D (5μm)

Product name
SUMIPAX ODS
Internal diameter(mm) Length(mm) Product code
D-216 4 150 AD216-4015W
D-217 4.6 150 AD217-4615W
D-211 4.6 250 AD211-4625W
D-215 6 100 AD215-6010W
D-212 6 150 AD212-6015W
D-214 6 300 AD214-6030W
D-213 10 250 AD21310025W
LC-MS size
D-210MS
2 150 AD210M2015W
Solvent saving size
D-210EC
3 150 AD210E3015W
  • Note : Please use SUMIPAX Filters for guard columns